FFA35RV1A
Power supply 1 phase, 220-240 V, 50 Hz
Indoor air ow rate H Cooling l/s

(cfm)

167 (353)
Heating 167 (353)
Indoor sound

pressure level

H/L Cooling dB(A) 36/29
Heating 36/28
Indoor sound power level H Cooling dB(A) 49
Heating 49
Fan speed 2 steps
Temperature control Microcomputer control
dimensions H x W x D mm 286 x 575 x 575
Machine weight kg 17.5
Piping connections Liquid ( are)  

mm

ø6.4
Gas ( are) ø9.5
Drain VP 20 (Inside diameter ø20, Outside diameter ø26)
Heat insulation Both liquid and gas pipes

Comfortable Airflow

  • Power-Airflow Flap
    The Power-Airflow Flap flattens out during cooling operation to deliver cool air to the corners of a room. The flap can direct warm air straight down to the floor during heating operation.
  • Power-Airflow Dual Flaps
    The Power-Airflow Dual Flaps can flatten out during cooling operation to deliver cool air to the corners of a room. The flaps can direct warm air straight down to the floor during heating operation.
  • Wide-Angle Louvers
    The Wide-Angle Louvers provide wide airflow coverage for effective operation no matter where the indoor unit is placed in a room.
  • Vertical Auto-Swing (up and down)
    This function automatically moves the flaps up and down to distribute air across a room.
  • Horizontal Auto-Swing (left and right)
    Horizontal Auto-Swing automatically moves the louvers to the left and right to cover a room with cool or warm air.
  • 3D Airflow
    This function combines Vertical and Horizontal Auto-Swing to circulate a cloud of cool or warm air right to the corners of even large spaces. The flaps and louvers swing in turn.
  • Comfort Airflow Mode
    This function prevents uncomfortable drafts from blowing directly on to the body. To prevent drafts, the flap moves upward during cooling operation and downward during heating operation.
  • Vertical Airflow (heating)
    When heating starts, the indoor unit delivers warm air to the corners and floor. Then, vertical airflow sends air along the walls and floor. This prevents drafts and increases comfort at floor level.

Cleanliness

  • Removable Drain Pan
    The drain pan collects condensation from the indoor heat exchanger fins. Removable drain pans help to reduce the cleaning time and ensure a perfect finish.
  • Flash Streamer Discharge Air Purifying
    The flash streamer discharge decomposes bacteria, viruses, allergic substances and mould adsorbed by the indoor unit’s deodorising filter. After the particles are trapped, they are irradiated by the streamer device.
  • Titanium Apatite Deodorising Filter
    This filter contains titanium apatite. While the filter’s micron- level fibres trap dust, the titanium apatite adsorbs odours and allergens, as well as deodorises odours. The filter can be used for up to three years with proper maintenance.
  • Mould-Proof Air Filter
    This filter is hygienic with a mould-proof treatment.
  • Wipe-Clean Flat Panel
    The flat panel design can be cleaned with only the single pass of a cloth across its smooth surface. The flat panel can also be easily removed for more thorough cleaning.
  • Filter Cleaning Indicator
    Dust deposited on the air filters is not only unhygienic, it also reduces the operating efficiency of the air conditioner. A message indicates when the air filters need cleaning.

Comfort Control

  • Indoor Unit Quiet Operation
    Indoor unit operating sound pressure levels can be decreased from the Low setting fan speed using the wireless remote controller.
  • Outdoor Unit Quiet Operation
    Outdoor unit operating sound pressure levels can be decreased from the rated operation sound using the wireless remote controller.
  • Night Quiet Mode
    Outdoor unit operating sound pressure levels are automatically decreased from the rated operation sound during cooling operation. It is effective when the outdoor temperature has dropped by 6°C from the maximum temperature recorded during the daytime. Initial setting is required during installation.
  • Automatic Operation
    This function automatically selects cooling or heating operation mode based on the room temperature at startup. This function is available with the reverse cycle type.
  • Intelligent Eye (auto energy saving)
    Intelligent Eye with its infrared sensor automatically controls air conditioner operation according to human movement in a room. When there is no movement for 20 minutes, it adjusts the temperature by approximately 2°C for energy savings.
  • Intelligent Eye (comfort)
    This function uses its infrared sensor to direct airflow away from people. If there is no human movement in a room for 20 minutes, it also automatically adjusts the set temperature by approximately 2°C to prevent energy wastage.
  • Intelligent Eye (focus and comfort)
    This function uses its infrared sensor to direct airflow either toward or away from people. If there is no human movement in a room for 20 minutes, it also automatically adjusts the set temperature by approximately 2°C to prevent energy wastage.
  • Programme Dry Function
    The microprocessor works to eliminate humidity while maintaining the most consistent temperature possible. It automatically controls the temperature and fan speed.
  • Auto Fan Speed
    The microprocessor automatically adjusts the fan speed to
    high to rapidly reach the set temperature. Once the temperature is achieved, this function reduces the fan speed to low.
  • Comfortable Auto Fan Speed
    This function automatically controls fan speed to achieve maximum efficiency and comfort. After rapidly cooling or warming a room using high speed, it switches to low. It then precisely adjusts speed to reduce humidity and ensure a comfortable balance between temperature and humidity.
  • Heat Plus
    Heat Plus delivers a direct flow of warm air for 30 minutes. It provides spot heating when returning home on a cold day. It is also convenient when changing clothes in the morning. This function is available with the reverse cycle type.
  • Hot-Start Function
    After defrosting or when starting heating operation, air is preheated before discharge to prevent uncomfortable cold drafts. This function is available with the reverse cycle type.

Lifestyle Convenience

  • Super Powerful
    This advanced function boosts airflow until the set temperature is reached. It is highly useful whenever rapid cooling or heating is needed. Capacity is immediately diverted to a unit when its Powerful button is pressed. After 20 minutes, the unit automatically returns to its previous settings.
  • Inverter Powerful Operation
    This function boosts cooling and heating performance for a 20 minute period. It is convenient when it is necessary to change the room temperature quickly.
  • Econo Mode
    This mode limits maximum power consumption. This improves operating efficiency and also prevents circuit breakers from being overloaded.
  • Priority Room Setting
    This function assigns preferential air conditioning to the indoor unit in the priority room. The unit is able to operate at a higher capacity than other units. It also receives priority control over Super Powerful and the operation mode.
  • Indoor Unit On/Off Switch
    The unit can be conveniently started by hand if the wireless remote controller is misplaced or its batteries are not charged.
  • Wireless Remote Controller with Backlight
    The backlit LCD allows easy operation in the dark. Frequently used functions are conveniently located on the front of the controller.
  • Daikin Mobile Controller (optional adaptor)
    This optional adaptor and its application turn a smartphone into a remote controller which can be used inside or outside the home. Together they help to maintain comfort while saving energy and eliminate any worries about forgetting to turn off the air conditioner. Functions are listed based on their use on the wireless remote controllers.

Worry Free

  • Auto-Restart after Power Failure
    The air conditioner memorises the settings for the operation mode (cooling, dry, heating, automatic and fan only), airflow, temperature, etc., and automatically returns to them when power is restored after a power failure.
  • Self-Diagnosis with Remote Controller
    Malfunction codes are shown on the digital display panel of the wireless remote controller for fast and easy maintenance.
  • Anti-Corrosion Treatment of Outdoor Heat Exchanger Fins
    The outdoor unit’ s heat exchanger fins are processed using a special anti-corrosion treatment. The surface is covered with a thin acrylic resin layer to enhance the fins’ resistance to acid rain and salt corrosion.

Timers

  • 24 Hour On/Off Timer
    This timer can start or stop the air conditioner within a 24 hour period. It can be preset in 10 minute steps by pressing the On/Off Timer button on the wireless remote controller. The On Timer and Off Timer can be used in combination.
  • 72 Hour On/Off Timer
    This timer can start or stop the air conditioner within a 72 hour period. It can be preset in one hour steps by pressing the programming timer button on the wireless remote controller. The controller is optional.
  • Weekly Timer
    The Weekly Timer allows up to four actions to be programmed for each day of the week. It is possible to schedule not only the on and off times, but also the desired temperatures during these periods. The copy function also makes the setting much easier and enables a daily programme to be repeated on other days as required.
  • Count Up-Down On/Off Timer
    The operation start and stop times can be set with the touch of a single button and preset for a period of one to 12 hours in one hour increments. When the Off Timer is set, Night Set Mode is activated automatically.
  • Night Set Mode
    Pressing the Off Timer button automatically selects Night Set Mode. This function prevents excessive cooling or heating for a pleasant sleep. After 60 minutes, the room temperature is raised by 0.5°C for cooling operation or lowered by 2°C for heating operation.

Others

  • Automatic Defrosting
    Before starting heating operation, a sensor checks for frost in the outdoor unit and performs automatic defrosting if necessary before air is discharged. This function is available with the reverse cycle type.

Click here to view the Brochure of Daikin FFA35RV1A 3.5kW Reverse Cycle Compact Cassette Multi indoor unit only

Completely Flat Finish

This discreet configuration allows the indoor unit to be installed completely flat to the ceiling. The unit is designed to fit inside a ceiling with a height of 300 mm or more and a ceiling grid of just 600 mm wide. This allows lights, speakers and sprinklers to be placed in adjoining ceiling tiles Daikin-Ceiling-Mounted-Cassette-Type-Completely-Flat-Finish

Draft Prevention Setting

The draft prevention setting stops air blowing directly on
to a person’s body. With this setting, flap movement can be limited to an arc of 0 to 35 degrees1. This helps to eliminate uncomfortable drafts while maintaining effective airflow.
Daikin-Ceiling-Mounted-Cassette-Type-Draft-Prevention-Setting

Soil Prevention Setting

This setting directs airflow away from the ceiling to prevent dust build-up and other marking. When it is selected, the flap arc is limited to a range of 25 to 60 degrees1. The result is a cleaner ceiling which requires minimal maintenance.
Daikin-Ceiling-Mounted-Cassette-Type-Soil-Prevention-Setting

 

Note: 1. Angles shown are provided as a guide. They may differ depending on the installation

Free Installation Position

Air discharge patterns including two to four directions can be selected according to the installation position.
Daikin-Ceiling-Mounted-Cassette-Type-Free-Installation-Position

Hot Start Function

After defrosting or when starting heating operation, air is preheated before discharge to prevent uncomfortable cold drafts.