CAPACITY | 5.0kW | |||
Indoor | DXK18ZSA-W | |||
Outdoor | DXC18ZSA-W | |||
Power Source (Outdoor Unit) | 1 Phase 240V 50Hz | |||
*Operation Data
|
Nominal Capacity (Range)
|
Cooling T1 |
kW
|
5.0 (1.2~5.5) |
Heating H1 | 5.8 (1.2~6.6) | |||
Heating H2 | 5.2 | |||
Power Consumption
|
Cooling T1 | 1.39 (0.27-1.86) | ||
Heating H1 | 1.49 (0.26~1.97) | |||
Maximum Power Consumption | 2.68 | |||
Running Current
|
Cooling T1 |
A
|
5.9 | |
Heating H1 | 6.3 | |||
Inrush Current, Maximum Current | 5.0, 14.5 | |||
EER | Cooling T1 | 3.6 | ||
COP | Heating H1 | 3.89 | ||
Sound Power Level (JIS C9612) | Outdoor |
dB(A)
|
61 | |
Sound Pressure Level (JIS C9612)
|
Indoor | 43-36-28-22 | ||
Outdoor | 49 | |||
Energy Label (GEMS 2019)
|
Hot
|
Cooling | -3.5 | |
Heating | -3.5 | |||
Average
|
Cooling | -3 | ||
Heating | -2.5 | |||
Cold
|
Cooling | -3 | ||
Heating | -2 | |||
External dimensions (HXWXD)
|
Indoor |
mm
|
290x870x230 | |
Outdoor | 640×800(+71)x290 | |||
Net weight
|
Indoor |
kg
|
10 | |
Outdoor | 43.5 | |||
Airflow
|
Cooling (Indoor) |
l/s
|
213-175-113-93 | |
Heating (Indoor) | 253-198-152-113 | |||
Installation Data
|
Refrigerant
(Type, Amount, Pre-charge Length) |
Quantity | kg | (R32) 1.05 |
Pre-Charged to Pipe | m | 15 | ||
Refrigerant Piping
|
Liquid line |
mm
|
Ø6.35 | |
Gas line | Ø12.7 | |||
Connection Method | Flare connection | |||
Maximum Pipe Length (One Way) |
m
|
25 | ||
Max Vertical Height Diff. Between O.U. and I.U. | 15 ( O.U. above I.U. ) / 15 ( O.U. below I.U. ) | |||
Standard accessories | Allergen Clear & Photocatalytic Washable Deodorizing Filter | |||
Optional parts | Interface kit (SC-BIKN2-E) / Wi-Fi Kit | |||
Demand Response (AS4755) | Yes |