DAIKIN FDYUAN160A-Y 15.5kW Inverter Underfloor Ducted System | Three Phase

SKU: FDYUAN160A-Y

15.5 kW Cooling
18.0 kW Heating

DAIKIN FDYUAN160A-Y 15.5kW Inverter Underfloor Ducted System | Three Phase

Includes:
Indoor Unit : FDYUAN160AV1
Outdoor Unit : RZA160CY1

Available Controller Options:

1. AirHub – Linear – Up to 4 Zones (24v) – Controller: BRCMTZCB9 / Zone Box: BRC24TLZ4B9
2. AirHub – Linear – Up to 8 Zones (24v) – Controller: BRCMTZCB9 / Zone Box: BRC24TLZ8B9
3. AirHub – On/Off – Up to 4 Zones (24v) – Controller: BRCMTZCB9 / Zone Box: BRC24TZ4B9
4. AirHub – On/Off – Up to 8 Zones (24v) – Controller: BRCMTZCB9 / Zone Box: BRC24TZ8B9

5. Zone Controller – Up to 4 Zones (230-240v) – Controller: Included in Zone Box / Zone Box: BRC230Z4B9
6. Zone Controller – Up to 8 Zones (230-240v) – Controller: Included in Zone Box / Zone Box: BRC230Z8B9
7. Zone Controller – Up to 4 Zones (24v) – Controller: Included in Zone Box / Zone Box: BRC24Z4B9
8. Zone Controller – Up to 8 Zones (24v) – Controller: Included in Zone Box / Zone Box: BRC24Z8B9




> > > > > Compare
INDOOR UNIT FDYUAN160AV1
OUTDOOR UNIT RZA160CY1
Rated Capacity Cool (kW) 15.5
Heat (kW) 18
Capacity Range Cool (kW) 7.3-16.3
Heat (kW) 7.3-18.2
Power Input (Rated) Cool (kW) 4.95
Heat (kW) 4.9
E.E.R/C.O.P C/H 3.13/3.67
TCSPF (Residential) Hot/Average/Cold 4.05/3.76/3.87
HSPF (Residential) Hot/Average/Cold 3.87/3.53/3.12
Airflow Rate (Nominal/Max) I/s 950/1120
Indoor Sound Level (H) @ 1.5m dBA (C/H) 47.9/50.7
Piping Length m 50
Indoor Fan Speeds H/M/L
Dimensions Indoor (mm) 360x1520x935
(HxWxD) Outdoor (mm) 1430x940x320
Indoor (kg) 56
Weight Outdoor (kg) 99
Power Supply V/HZ 3 Phase, 380-415V, 50Hz
Compressor Type Hermetically Sealed Swing Type
Refrigerant R32
Pipe Sizes Liquid (mm) 9.5 (Flared)
Gas (mm) 15.9 (Flared)
Drain (mm) ID 25 / OD 32
Supply Air Opening mm (HxW, Flange) 245×1152
Return Air Opening mm 2×400 (Oval)
Outdoor Operating Range Cool (OCDB) -5 to 46
Heat (OCWB) -15 to 16
EPA Sound Power Level dBA 75
Outdoor Sound Level (H) @ 1m Pressure dBA (C/H) 56/58

Inverter Underfloor Ducted

Improved energy performance

Adopting advanced technologies such as a DC Fan motor, Cross-Pass Heat Exchanger on the outdoor unit with increased heat exchange area and Daikin’s patented swing compressor our new Inverter series is designed to operate with improved efficiencies throughout the year.

Space saving outdoor unit

The Inverter series outdoor units are more compact than ever before. Models up to 125 Class are now encased in a space saving single fan side discharge outdoor unit, allowing you to easily place the unit under windows.

Compact indoor unit

Today’s modern home designs are maximising living spaces with higher ceilings resulting in shallower roof spaces. Our Inverter series features compact indoor units with a low profile height of ≤360mm allowing them to fit comfortably into modern homes.

3 phase option

Designed for homes with a 3 phase power supply in place, our R32 Underfloor Inverter series ensures a simple and convenient installation without the need to worry about unbalanced electrical loads at your electrical distribution board.

DAIKIN Ducted Air Conditioner Systems Features

Download the brochure of DAIKIN FDYUAN160A-Y 15.5kW Inverter Underfloor Ducted System | Three Phase

Daikin Underfloor Ducted Systems

Daikin’s Underfloor Ducted Systems are an ideal solution for homes in colder climates where heating is a focus. In these situations, units are typically installed underfloor to promote even warm air distribution throughout the home. Now utilising R32 refrigerants for lower GWP impact, Daikin’s Underfloor Systems are the perfect balance of energy performance and home comfort when paired with Daikin’s Zone Controllers.

Why is R32 underfloor different?

The Daikin Underfloor Ducted System has been engineered to ensure the safety of all occupants. The system incorporates a leak detector that activates Daikin’s Refrigerant Control Strategy in the unlikely event of a refrigerant leak. This sophisticated new built-in monitoring and control technology works to dissipate leaks in order to eradicate any flammability hazards, ensuring the system complies with Australian and New Zealand standard 60335.2.40:2019.

How does it work?

1. Upon activation of the leak detector, a signal is sent to the Daikin controller
2. Daikin controller will then operate the system to dissipate the refrigerant from the ducted system:

  • Compressor is switched off
  • Indoor unit fan operates in fan only mode
  • All zone dampers are open

Description

15.5 kW Cooling
18.0 kW Heating

New Model | R32

Daikin Controller

We have a range of controllers available to control your DAIKIN ducted air conditioning system to suit your lifestyle needs.

ZONE CONTROLLER

(On/Off Control Only)

Zone Controller Models:
BRC230Z4B9 – Up to 4 Zones (230-240v)
BRC230Z8B9 – Up to 8 Zones (230-240v)
BRC24Z4B9   – Up to 4 Zones (24v)
BRC24Z8B9   – Up to 8 Zones (24v)

FEATURES
1. Backlit display with easy-to-read text.
2. Three different timer and time clock operations for precise, programmable control for your home.
3. Countdown On-Off timer, programmable in 1 hour increments for up to 12 hours.
4. A simple 7-day Time Clock, to program the controller to turn the system on or off at set times any day of the week. Two different on and off programs can be set for each day of the week.
5. An advanced 7-day Time Clock extends the functionality of the Simple 7-day Time Clock with advanced features such as Zone Control and Temperature Sensor Selection, for the ultimate in-home comfort.
6. Airside Control when connected with Premium Inverter (71-250 Class) & Inverter (50-160 Class) Ducted models.

Notes:
1. Airside Control function regulates the fan RPM between 60% to 100% of the indoor unit’s rated airflow
2. Airbase is not compatible with Slave Zone Controller

Daikin AirHub

Features:

  • 7” colour resistive touch screen interface housed in a contemporary casing design with a matte white finish.
  • Both On/Off or Linear Control options available in either a 4 or 8 zone design.
  • Flush mounted 11mm off the wall for a clean, minimalistic look.
  • Weekly Schedule Timer with individual zone timer, for programming the system and individual zones on or off at set times of the week.
  • Optional wireless remote temperature sensors, ideal for homes with internal brick walls.
  • Eco settings such as Setpoint Range Limit, Setpoint Auto Reset and Auto Off Timer enables you to easily reduce your ducted system’s energy consumption.

What is Airside Control?
As zones are turned off, the indoor unit fan reduces speed between 60-100% of the nominal airflow rate to meet the airflow requirement of the remaining open zones for quieter operation and greater energy savings.

What is Optizone Control?

OptiZone Control will automatically regulate the individual zone dampers to deliver precise airflow to meet the temperature settings and heat load of each zone. As the zone dampers adjust, the indoor unit fan speed will intelligently regulate between 30-100% of the nominal airflow rate to deliver the required airflow to maintain the comfort levels of each zone.

On days when the heat load is mild or low, significant energy savings can be achieved through OptiZone Control, truly optimising the system for ultimate comfort.