Supplying Since 2012

Apac S015ILR / S015OVR 15.54 kW Split Ducted Unit (Low Profile)
15.54 kW Cooling | 14.70 kW Heating
Apac S015ILR / S015OVR 15.54 kW Split Ducted Unit (Low Profile)
- High static capability up to 500pa
- Quieter operation with 12db(A) sound reduction
- Condenser coil anti-corrosion protection | MEPS Compliant
5 Years Manufacturer’s Warranty
- Specification
- Features
- Brochure
- Additional information
- Reviews
|
Model Number (Reverse Cycle)
|
Indoor Unit | S015ILR |
| Outdoor Unit | S015OVR | |
|
Rated Cooling
|
Total Capacity (kW)3 | 15.54 |
| Sensible3 | 12.13 | |
| EER (kW/ikW)3 | 3.7 | |
|
Rated Heating1
|
Total Capacity (kW) | 14.7 |
| COP | 3.87 | |
| MEPS Certified | Yes | |
|
Operating Range
|
Maximum °C | 50 |
| Minimum °C | -10 | |
| Capacity Steps | % | 0/100 |
|
Compressor
|
Type | Scroll |
| Starter | D.O.L (Optional Soft Starter) | |
| Qty | 1 | |
|
Outdoor Fan
|
Type | Hybrid Axial |
| Speed Control | Pressure Transducer | |
| Qty | 2 | |
|
Refrigerant System
|
Type | R410A |
| Charge Per Circuit kg | 5.3 | |
| No of Circuits | 1 | |
|
Indoor Fan
|
Type | EC Centrifugal Blower |
| Speed Control | Variable Speed | |
| Qty | 1 | |
|
Airflow Indoor (L/s)
|
Nominal | 835 |
| Maximum | 1044 | |
| Minimum | 626 | |
| Available External Static Pressure |
Pa | +200 Pa |
| IP Rating | IP44 | |
| Power Supply | (Volt/Phase/Hz) | 400-415V / 3Ph + N / 50Hz |
| Rated Load Amps4 | Outdoor/Indoor/ Total |
7.5/ 2.8/ 11.3 |
| Full Load Amps5 | Outdoor/Indoor/ Total |
12/4.4/16.4 |
|
Outdoor Dimensions (mm)
|
Height | 1162 |
| Width | 730 | |
| Length | 1550 | |
|
Indoor Dimensions (mm)
|
Height | 444 |
| Width | 1225 | |
| Length | 655 | |
|
Indoor and Outdoor Pipe Connection Diameter
|
Liquid mm (inch) | 9.5 (3/8″) x 1 |
| Gas mm (inch) | 19.1 (3/4″) x 1 | |
| Nominal Weight 2. | Outdoor kg | 214 |
| Nominal Weight 2. | Indoor kg | 70 |
|
Rated Sound Power
|
db(A)
|
61.7
|
1. For reverse cycle model only
2. For base model only. Factory options will vary
3. Performance excludes ikW of evaporator fan motor
4. R.L.A – Run Load Amps are based on current drawn at nominal conditions
5. F.L.A – Full Load Amps are based on the overload settings [max current] of all compressor and fan motor(s)
Features
- Low profile space saving design suitable for in-ceiling installation
- EC direct drive centrifugal blower (12-23kW)
- EC plug fans 024-045 with high static capability up to 500pa
- Hybrid axial fan (12-45kW)
- TXV refrigerant control
- Condenser coil anti-corrosion protection
- Open controls
- 25mm PE closed cell insulation
- Phase fail protection relay
- MEPS certified
Factory options customised to order Outdoor
- Compressor soft starter
- Copper/copper coil(s)
- Capacity modulation control
- High static pressure outdoor fans
- Outdoor coil(s) with anti-corrosion post-treatment
- Outdoor coil guards, powder coated
- Discharge & suction isolation valves
- High Level Interface (HLI) Modbus connectivity
- Cable markers
Indoor
- Double layered insulation to indoor section
- Copper/copper coil(s)
- Indoor coil(s) with anti-corrosion post-treatment
Factory options engineered to order Outdoor
- 316 stainless steel cabinet, unpainted
- 304 stainless steel cabinet, powder coated
- Stainless steel external fixings
- Coil(s) copper / copper
- Power supply – no neutral (415/3/50)
- Ductable air off in lieu of standard axial
Indoor - Stainless steel external fixings
- Coil(s) copper / copper
- Power supply – no neutral (415/3/50)
- R22/R407C application
Additional information
| Weight | 284 kg |
|---|---|
| kW | 10 |