Supplying Since 2012

ActronAir Advance B CRV19BT | EVV19BS 19.36kW Split Ducted System Air Conditioner | 3 Phase
ActronAir Advance B CRV19BT / EVV19BS 19.36kW Split Ducted System Air Conditioner | 3 Phase
Includes Indoor EVV19BS – 8 Zone Integrated & 20m CAT5E Cable – Yellow | Outdoor CRV19BT
Optional Controllers NEO TOUCH Master Wall Controller (Black/White) / 7 day wall controller (White/Grey)
Optional Horizontal Discharge Outdoor Unit
Optional Zone Barrels:
- ZB-10-250 – Zone Barrel 10 INCH – 250MM (Includes 7m CAT5E zone cable)
- ZB-12-300 – Zone Barrel 12 INCH – 300MM (Includes 7m CAT5E zone cable)
- ZB-14-350 – Zone Barrel 14 INCH – 350MM (Includes 7m CAT5E zone cable)
- ZB-16-400 – Zone Barrel 16 INCH – 400MM (Includes 7m CAT5E zone cable)
Optional Plenums:
- Supply PL34S-2/45S 2 x 450mm (18″) spigot – PL21R-2/40S Return 2 x 400mm (16”) spigot
- Supply PL22S-3/35S 3 x 350mm (14”) spigot – PL21R-2/40S Return 2 x 400mm (16”) spigot
- Supply PL30S-3/40S 3 x 400mm (16”) spigot – PL21R-2/40S Return 2 x 400mm (16”) spigot
- Supply PL34S-3/45S 3 x 450mm (16”) spigot – PL21R-2/40S Return 2 x 400mm (16”) spigot
- Supply PL21S-2/40S 2 x 400mm (16”) spigot – PL21R-2/40S Return 2 x 400mm (16”) spigot
Optional Insulated Copper Pair Coil
5 Years Manufacturer’s Warranty
- Specification
- Features
- Brochure
- Description
- Faqs
- Additional information
- Reviews
|
Model
|
Outdoor | CRV19BT |
| Indoor | EVV19BS | |
|
(1)Total (Gross) Capacity (kW) (AS/NZS3823.1.2)
|
Cooling (Rated) | 19.36 |
| Heating (Rated) | 18.64 | |
|
Nett (Rated) Capacity (kW) (AS/NZS3823.1.2)
|
Cooling (Min/Rated/Max) | 6.48 / 19.00 / 21.00 |
| Heating (Min/Rated/Max) | 5.58 / 19.00 / 20.00 | |
|
Input Power (kW) (AS/NZS3823.1.2)
|
Cooling (Rated) | 5.54 |
| Heating (Rated) | 5.08 | |
| (2)EER Rated (AS/NZS3823.1.2) | Cooling (Rated) | 3.43 |
| (3)COP Rated (AS/NZS3823.1.2) | Heating (Rated) | 3.74 |
|
Power Supply – (V/Ph/Hz)
|
Outdoor | 400V / 3Ph + N / 50Hz |
| Indoor | 230V / 1PH + N / 50Hz | |
| Rated Amps (AS/NZS3823.1.2) | Total | 11 |
| Full Load Amps (AS/NZS3823.1.2) | Outdoor / Indoor / Total | 12.48 / 4.63 / 17.11 |
| (4)Circuit Breaker Amps (Suggested) | 20 | |
|
IP Rating
|
Outdoor | IP44 |
| Indoor | IP20 | |
|
Compressor
|
Type / No. Unit |
Inverter Variable Speed Scroll / 1
|
| Starting Method | Inbuilt Soft Starting | |
| No. of Refrigeration Circuits / No. of Capacity Stages | 1 / Variable Capacity | |
| Refrigerant | R32 | |
|
Fans (Type x Number per Unit)
|
Outdoor | Axial / EC Motor x 2 |
| Indoor | Twin Centrifugal / EC Motor x 1 | |
|
Airflow Indoor (l/s)
|
Maximum | 1200 |
| Nominal | 1000 | |
| Minimum | 375 | |
|
Outdoor Dimensions (mm)
|
Depth | 530 |
| Height | 1110 | |
| Width | 1365 | |
|
Indoor Dimensions (mm)
|
Depth | 645 |
| Height | 485 | |
| Width | 1470 | |
|
(5)Nominal Weights (kgs)
|
Outdoor | 142 |
| Indoor | 75 | |
| (6)Sound Pressure Level (dBA) @ 1m | Outdoor (quiet/rated/max) | 57.70 / 65.60 / 65.60 |
| (7)Sound Power Level (dBA) | Outdoor (quiet/rated/max) | 69.00 / 77.50 / 77.50 |
| MEPS Compliant | Yes | |
| Demand Response Capability (AS4755.3) | Yes | |
| BMS and Home Automation Compatibility (ICUNO-MOD) | Yes | |
| Hydrophilic Blue Fin Coil Coat Protection – Indoor & Outdoor Coils | Yes | |
| Home Automation / Remote On / Off Capability | Yes | |
| Manual Inputs Capable for Third party Control | Yes | |
| Maximum Number of Zones | 8 | |
| Run & Fault Indication | Yes | |
| Two Piece Indoor Option | Yes | |
| Operating Range
Copper Pipe |
-15oC up to 52oC
22.22mm (7/8″) | 12.7mm (1/2″) Cut to fit 9.52mm (3/8″) field pipe |
|
Quiet and Efficient Indoor Fan
The AIRES indoor fan ensures precise, energy-saving air delivery, smoother operation, and quieter starting and stopping.
Maintain comfort without running up your bills.
Using inverter technology, the AIRES system will automatically adjust its capacity to provide only the conditioning that is required, thereby reducing your running costs.
Tested by Australia
Tried and tested to handle the extremes of the Aussie climate, AIRES is easily capable of delivering energy-saving comfort whether in the oppressive heat or the biting cold.
Engineered in Australia
Unlike most overseas air conditioners with a maximum operating temperature range of 43°C to 46°C, we test our AIRES units to ensure they can easily operate from -10°C up to 50°C.*
Quiet Mode
AIRES features Quiet Mode that enables you to operate your system at reduced noise levels, ensuring a peaceful environment for both you and your neighbours.
* Quiet mode is inactive when operating in heating mode at outdoor temperatures below 10°C, or in cooling mode at outdoor temperatures above 35°C.
*Operating range based on air temperature entering the outdoor unit heat exchanger.
Turbo Mode
Turbo Mode function offers instant relief as your air conditioner kicks into high gear, delivering extra capacity power when you need it most.
Performance
High Seasonal Performance Factor
The outside temperature affects the performance and efficiency of all air conditioners – so AIRES has been designed with all of Australia’s extreme conditions in mind.
R32 Refrigerant
AIRES utilises R32, with a substantially lower Global Warming Potential than some alternative refrigerants, while enjoying the benefits of optimised energy efficiency.
Adaptive Dry Mode
Adaptive Dry Mode cleverly fine-tunes the system by adjusting to real conditions, removing just the right amount of moisture. It’s smart, efficient way to maintain comfort, even as humidity levels change.
Description
19.36 kW Cooling
18.64 kW Heating
Quiet Operation | Variable Fan Technology
Q1: What are the main features of the Two Piece Indoor Split Ducted Systems – Three Phase ADVANCE Series?
The Two Piece Indoor Split Ducted Systems – Three Phase ADVANCE Series features a compact design, Flexible Zoning, Unity IQ Logic, Quiet Mode, Adaptive Dry Mode, Turbo Mode, a quiet and efficient indoor fan, inverter technology, and R32 refrigerant. It is engineered and tested for Australian conditions to deliver reliable year-round heating and cooling performance.
Q2: Is the Two Piece Indoor Split Ducted Systems – Three Phase ADVANCE Series energy efficient?
Yes. The Two Piece Indoor Split Ducted Systems – Three Phase ADVANCE Series uses advanced inverter technology to automatically adjust its capacity based on your heating and cooling requirements, helping reduce running costs while maintaining consistent indoor comfort. It also features a high Seasonal Performance Factor and environmentally friendlier R32 refrigerant for improved energy efficiency.
Q3: Does the Two Piece Indoor Split Ducted Systems – Three Phase ADVANCE Series offer advanced comfort technology?
Yes. The Two Piece Indoor Split Ducted Systems – Three Phase ADVANCE Series includes Unity IQ Logic, Flexible Zoning, Adaptive Dry Mode, and Turbo Mode to deliver intelligent climate control, balanced airflow, rapid temperature adjustment, and enhanced comfort throughout your home or commercial property.
Q4: Is the Two Piece Indoor Split Ducted Systems – Three Phase ADVANCE Series suitable for Australia’s climate?
Yes. The Two Piece Indoor Split Ducted Systems – Three Phase ADVANCE Series is engineered and tested specifically for Australian conditions, operating reliably in temperatures from -10°C to 50°C. Its Quiet Mode, efficient indoor fan, and advanced airflow management help maintain comfortable indoor conditions throughout Australia’s changing seasons.
Q5: Not sure what size air conditioner you need?
Use our free Air Conditioning Calculator & Size Guide as a starting point to estimate the right capacity for your room or home. Please note this calculator is a guide only — actual requirements may vary depending on your ceiling height, insulation, window size, orientation, and local climate conditions.
For a more accurate sizing recommendation tailored to your specific home or office, we recommend booking a quote with our team. Our air conditioning experts will assess your space and help you choose the perfect Two Piece Indoor Split Ducted Systems – Three Phase ADVANCE Series unit with confidence — ensuring maximum comfort, efficiency, and value for money.
For more information about the ActronAir Two Piece Indoor Split Ducted Systems – Three Phase ADVANCE Series, and available models, click here.
Additional information
| Weight | 224 kg |
|---|---|
| Select Controller | No Controller, LR7-1W 7 day wall controller (WHITE) – 8 Zone, LR7-1G 7 day wall controller (GREY) – 8 Zone, NTB-1000 NEO TOUCH Master Wall Controller (BLACK), NTW-1000 NEO TOUCH Master Wall Controller (WHITE) |








