Indoor | DXK24ZRA-WF1 | ||||
Outdoor | DXC24ZRA-W | ||||
Power source (Outdoor Unit) | 1 Phase 240V 50Hz | ||||
*Operation data
|
Nominal Capacity (Range)
|
Cooling T1 |
kW
|
7.1 (2.3~8.3) | |
Heating H1 | 8.0 (2.0~10.9) | ||||
Heating H2 | 8.1 | ||||
Power consumption
|
Cooling T1 |
kW
|
1.84 (0.48~2.4) | ||
Heating H1 | 2.02 (0.4~3.4) | ||||
Maximum power consumption | kW | 3.65 | |||
Running current
|
Cooling T1 |
A
|
7.8 | ||
Heating H1 | 8.6 | ||||
Inrush current, maximum current | A | 8.6, 17.0 | |||
EER | Cooling T1 | 3.86 | |||
COP | Heating H1 | 3.96 | |||
Sound power level (JIS C9612) | Outdoor | dB(A) | 65 | ||
Sound pressure level (JIS C9612)
|
Indoor |
dB(A)
|
43-40-36-24 | ||
Outdoor | 53 | ||||
Energy label (GEMS 2019)
|
HOT
|
Cooling | 4 | ||
Heating | 3 | ||||
AVERAGE
|
Cooling | 3.5 | |||
Heating | 2.5 | ||||
COLD
|
Cooling | 3.5 | |||
Heating | 2 | ||||
External dimensions (HxWxD)
|
Indoor |
mm
|
339x1197x262 | ||
Outdoor | 750×880(+88)x340 | ||||
Net weight
|
Indoor |
kg
|
15.5 | ||
Outdoor | 58 | ||||
Airflow
|
Indoor (Cooling) |
l/s
|
342-310-270-174 | ||
Indoor (Heating) | 425-330-288-222 | ||||
Refrigerant (Type, amount, pre-charge length)
|
Quantity | kg | (R32) 1.6 | ||
Pre charged to pipe length | m | 15 | |||
Installation data
|
Refrigerant piping
|
Liquid line |
mm
|
Ø6.35 | |
Gas line | Ø15.88 | ||||
Connection method | Flare connection | ||||
Maximum pipe (one way) length | m | 30 | |||
Max vertical height diff. between O.U. and I.U. | m | 20 ( O.U. above I.U. ) / 20 ( O.U. below I.U. ) | |||
Standard accessories | Allergen clear filter , NOVAShield Nano filter (PM2.5), Built-in Wi-Fi | ||||
Optional parts | Interface kit (SC-BIKN2-E) | ||||
Demand response (AS4755) | Yes | ||||
* Operation data are conducted in accordance with AS/NZS 3823 standard. For testing conditions please refer to Page xxx |