CAPACITY | 2.5kW | |||
Indoor | DXK09ZSA-W | |||
Outdoor | DXC09ZSA-W | |||
Power Source (Outdoor Unit) | 1 Phase 240V 50Hz | |||
*Operation Data
|
Nominal Capacity (Range)
|
Cooling T1 |
kW
|
2.5 (0.9~3.5) |
Heating H1 | 3.2 (0.9~5.2) | |||
Heating H2 | 3.95 | |||
Power Consumption
|
Cooling T1 | 0.51 (0.18~0.88) | ||
Heating H1 | 0.65 (0.21~1.43) | |||
Maximum Power Consumption | 1.65 | |||
Running Current
|
Cooling T1 |
A
|
2.5 | |
Heating H1 | 3 | |||
Inrush Current, Maximum Current | 3.2, 9.0 | |||
EER | Cooling T1 | 4.9 | ||
COP | Heating H1 | 4.92 | ||
Sound Power Level (JIS C9612) | Outdoor |
dB(A)
|
58 | |
Sound Pressure Level (JIS C9612)
|
Indoor | 40-31-22-19 | ||
Outdoor | 45 | |||
Energy Label (GEMS 2019)
|
Hot
|
Cooling | -4.5 | |
Heating | -3.5 | |||
Average
|
Cooling | -3.5 | ||
Heating | -3 | |||
Cold
|
Cooling | -3.5 | ||
Heating | -3 | |||
External dimensions (HXWXD)
|
Indoor |
mm
|
290x870x230 | |
Outdoor | 540×780(+62)x290 | |||
Net weight
|
Indoor |
kg
|
10 | |
Outdoor | 36 | |||
Airflow
|
Cooling (Indoor) |
l/s
|
182-140-88-78 | |
Heating (Indoor) | 237-182-110-88 | |||
Installation Data
|
Refrigerant
(Type, Amount, Pre-charge Length) |
Quantity | kg | (R32) 0.78 |
Pre-Charged to Pipe | m | 15 | ||
Refrigerant Piping
|
Liquid line |
mm
|
Ø6.35 | |
Gas line | Ø9.52 | |||
Connection Method | Flare connection | |||
Maximum Pipe Length (One Way) |
m
|
20 | ||
Max Vertical Height Diff. Between O.U. and I.U. | 10 ( O.U. above I.U. ) / 10 ( O.U. below I.U. ) | |||
Standard accessories | Allergen Clear & Photocatalytic Washable Deodorizing Filter | |||
Optional parts | Interface kit (SC-BIKN2-E) / Wi-Fi Kit | |||
Demand Response (AS4755) | Yes |