Daikin Mono-Bloc EBLA14DA3 12.7kW Reverse Cycle Altherma System Air Conditioner

0 out of 5

$12,475.00

Daikin Mono-Bloc EBLA14DA3 12.7kW Reverse Cycle Altherma System Air Conditioner. The EBLA14DA3 model offers high performance for both cooling and heating requirements.

  • System: EBLA14DA3
  • Outdoor Unit: EBLA14DA3V3
  • Flow Switch: EKFLSW1
  • Efficient Heating
  • Safe R32 Refrigerant
  • Flexible Connection
SKU: EBLA14DA3
INDOOR UNIT (HYDRO BOX) –
OUTDOOR UNIT EBLA14DA3V3
Rated Capacity Heat (kW) 12.00
Cool (kW) 12.70
Rated Input Heat (kW) 2.46
Cool (kW) 2.51
Leaving water temperature range Heat (°C) 15 to 60
Cool (°C) 5 to 22
Casing Material Indoor (mm) –
Outdoor (mm) Painted Galvanised Steel Plate
Colour Indoor –
Outdoor Light Grey (Black Grille)
Electric booster heater (kW) 3
COP (Heating Efficiency) 4.88
EER (Cooling Efficiency) 5.06
Dimensions (HxWxD) Indoor (mm) –
Outdoor (mm) 870x1380x460
Weight Indoor (kg) –
Outdoor (kg) 149
Outdoor operation range Heat (°C) -25 to 35
Cool (°C) 10 to 43
Refrigerant charge R32 (kg) 3.8
Power supply 1 Phase, 230V, 50Hz
Indoor sound pressure level (dBA) –
Outdoor EPA sound power level Heat (dBA) 62

 

Efficient Heating

Utilises free heat from the ambient air to maintain ideal comfort conditions in your home. In addition, the inverter technology inherent in Atherma means your energy savings are even greater.

Safe

Works without the need for oil, flammable gas (LPG, Natural) or other hazardous substances thus reducing the potential risks that these fuels can create. Furthermore, there is no need for a gas connection or a fuel tank.

R32 Refrigerant

Enables increased energy efficiency and a significant reduction in ‘Global Warming Potential Factor’ – great for the environmentally conscious.

Flexible Connection

Compatibility with a range of third-party fan coils, radiators, and underfloor heat emitters ensures the optimal solution can be tailored to your home.

Powerful Operation

Even in the coldest weather, the Altherma system is still able to extract heat energy from the ambient air. In the event there is insufficient heat in the outdoor air, Altherma is equipped with a backup heater to cover the shortfall.

Zone Control

System controller offers the ability to control the individual water temperature of up to two zones or emitters – ideal for meeting the varying cooling or heating needs of occupants.

Description

Efficient heating | Flexible Connection

Q1: What are the main features of the Altherma Systems Reverse Cycle Mono-Bloc R32 Hot Water Heat Pump?

The Altherma Systems Reverse Cycle Mono-Bloc R32 Hot Water Heat Pump is designed to provide efficient and environmentally friendly heating and hot water solutions for residential applications. The Altherma Systems Reverse Cycle Mono-Bloc R32 Hot Water Heat Pump features inverter technology, R32 refrigerant, flexible compatibility with fan coils, radiators, and underfloor heating systems, powerful low-temperature operation, and advanced zone control for customised comfort throughout the home.

Q2: Is the Altherma Systems Reverse Cycle Mono-Bloc R32 Hot Water Heat Pump energy efficient?

Yes. The Altherma Systems Reverse Cycle Mono-Bloc R32 Hot Water Heat Pump utilises free heat energy from the ambient air and advanced inverter technology to maximise efficiency and reduce energy consumption. It also uses environmentally friendly R32 refrigerant, helping to lower running costs while reducing environmental impact.

Q3: Does the Altherma Systems Reverse Cycle Mono-Bloc R32 Hot Water Heat Pump include temperature control features?

Yes. The Altherma Systems Reverse Cycle Mono-Bloc R32 Hot Water Heat Pump includes advanced zone control capabilities that allow independent water temperature management for up to two separate zones or emitters. The Altherma Systems Reverse Cycle Mono-Bloc R32 Hot Water Heat Pump provides flexible comfort control to suit the varying heating requirements of different areas within the home.

Q4: Is the Altherma Systems Reverse Cycle Mono-Bloc R32 Hot Water Heat Pump suitable for reliable and safe operation?

Yes. The Altherma Systems Reverse Cycle Mono-Bloc R32 Hot Water Heat Pump is designed for safe and dependable operation without the need for oil, LPG, natural gas, or other hazardous fuels. The Altherma Systems Reverse Cycle Mono-Bloc R32 Hot Water Heat Pump can continue delivering effective heating performance even during cold weather conditions, with a built-in backup heater available when additional heating support is required.

Q5: Not sure what size air conditioner you need?

Use our free Air Conditioning Calculator & Size Guide as a starting point to estimate the right capacity for your room or home. Please note this calculator is a guide only — actual requirements may vary depending on your ceiling height, insulation, window size, orientation, and local climate conditions.

For a more accurate sizing recommendation tailored to your specific home or office, we recommend booking a quote with our team. Our air conditioning experts will assess your space and help you choose the perfect Altherma Systems Reverse Cycle with confidence — ensuring maximum comfort, efficiency, and value for money.

For more information about the Altherma Systems Reverse Cycle Series, and available models, click here.

Additional information

Weight 155 kg
kW

12