LGH-80RVS-E |
||||||
Weight |
63kg (77kg with maximum drain water) |
|||||
Electrical Power Supply |
220 – 240V/50Hz, 220V/60Hz |
|||||
Fan Speed Input Power |
W |
100% |
75% |
50% |
25% |
Test condition |
325 |
175 |
85 |
32 |
ISO 16494 Temperature exchange efficiency is winter condition |
||
Airflow |
m3/h |
800 |
600 |
400 |
200 |
|
L/S |
222 |
167 |
111 |
56 |
||
Specific Fan Power |
W/(L/S) |
1.46 |
1.05 |
0.77 |
0.58 |
|
External Static Pressure |
Pa |
170 |
96 |
43 |
11 |
|
Temperature Exchange Efficiency % |
82.0 |
84.0 |
86.0 |
90.0 |
||
Noise |
dB |
36.0 |
30.0 |
25.0 |
18.0 |
A-weighted sound pressure level @1.5m off from the center of the unit in an anechoic chamber |
Exhaust Air Transfer Ratio % Insulation Resistance |
5 |
Tracer gas method @100% airflow (prEN308) |
||||
10MΩ or more |
||||||
Dielectric Strength Maximum Current |
A |
AC 1000V 1 minute |
||||
3.70 |
||||||
Inrush Current |
A |
6.1A @10ms, 3.6A @100ms |