MODEL | LGH-200RVXT-E | SIGN | |||||||||||||||
Heat exchange system | Heat recovery ventilating system | ||||||||||||||||
Heat exchanger material | Special treated paper plate heat exchanger | ||||||||||||||||
Cladding | Galvanized steel sheet | ||||||||||||||||
Heat insulation material | Self-extinguishing urethane foam | ||||||||||||||||
Motor | EC motor | ||||||||||||||||
Blower | 245mm diameter centrifugal fan | ||||||||||||||||
Filter | Non-woven fabrics filter (Gravitational method 82% EU-G3) | ||||||||||||||||
Surrounding air condition | Shall be between -10℃ and 40℃, 80%RH or less | ||||||||||||||||
Suction air condition | Shall be lower than 40℃, 80%RH | ||||||||||||||||
Supply fan operation under low outdoor temperature |
-10℃ to -15℃ : Intermittent operation 60 min ON, 10 min OFF. -15℃ or less : Intermittent operation 55 min OFF, 5 min ON. |
||||||||||||||||
Function | Heat recovery ventilation/ Bypass ventilation, Fan speed 1,2,3,4 | ||||||||||||||||
Weight | 159kg | ||||||||||||||||
Electrical power supply | 220-240V/50Hz, 220V/60Hz | ||||||||||||||||
Ventilation mode | Heat recovery mode | Bypass mode | |||||||||||||||
Fan speed | SP4 | SP3 | SP2 | SP1 | SP4 | SP3 | SP2 | SP1 | |||||||||
Running current [A] | 5.40 | 2.70 | 1.10 | 0.39 | 5.00 | 2.20 | 0.85 | 0.34 | |||||||||
Input power [W] | 1,000 | 494 | 197 | 56 | 916 | 407 | 150 | 45 | |||||||||
SFP [W/(L/s)] | 1.8 | 1.2 | 0.7 | 0.4 | 1.6 | 1.0 | 0.5 | 0.3 | |||||||||
Air volume | [m3/h] | 2,000 | 1,500 | 1,000 | 500 | 2,000 | 1,500 | 1,000 | 500 | ||||||||
[L/s] | 556 | 417 | 278 | 139 | 556 | 417 | 278 | 139 | |||||||||
External static pressure |
Supply [Pa] | 175 | 98 | 44 | 11 | 175 | 98 | 44 | 11 | ||||||||
Return [Pa] | 100 | 56 | 25 | 6 | 100 | 56 | 25 | 6 | |||||||||
Exchange efficiency [%] |
Temperature | 80.0 | 81.0 | 82.5 | 84.0 | – | – | – | – | ||||||||
Enthalpy | Heating | 72.5 | 73.5 | 77.0 | 83.0 | – | – | – | – | ||||||||
Cooling | 70.0 | 71.0 | 74.5 | 80.5 | – | – | – | – | |||||||||
Noise [dB] | 39.5 | 35.5 | 28.0 | 22.0 | 40.5 | 34.5 | 27.0 | 20.5 | |||||||||
Insulation resistance | 10MΩ or more | ||||||||||||||||
Direct strength | AC 1500V 1 minute |
Mitsubishi Electric Lossnay LGH-200RVXT-E Low-Profile – 556 L/s Heat Recovery Ventilation
Mitsubishi Electric Lossnay LGH-200RVXT-E – 556 L/s Low-Profile Heat Recovery Ventilation
Includes Indoor LGH-200RVXT-E Lossnay | Includes a Lossnay Wired 7 Day Controller PZ-62DR-EB
Lossnay Ventilation Mode | Filter (Supplied) | Energy efficient
1 Year Manufacturer’s Warranty
The Lossnay Fresh Air Energy Recovery Systems set a new standard in ventilation by recovering heat from the air inside your office and transferring it to fresh, dry air introduced from outside. Not only providing energy recovery savings in summer by cooling the warmer fresh air to an acceptable level but also providing excellent energy efficiency in winter. Lossnay heat exchangers have a high efficiency thereby eliminating the need for additional electric elements.
Simultaneous air supply and exhaust
Lossnay is the ultimate home ventilation system that provides fresh clean air from outside, while removing both moisture and stale indoor air at the same time. Bringing in fresh air into the house can help improve air quality by lowering the amount of CO2.
Heat recovery ventilation
Heat is recovered from the outgoing stale air. This heat is utilised to pre-heat incoming fresh air so your heating system is not required to work as hard to maintain desired room temperature.
Use with Mr Slim & City Multi Systems
Lossnay can be integrated and interlocked with a Mitsubishi Electric Mr. Slim and City Multi air conditioning systems. The ducted system provides heating and cooling while the Lossnay ventilator brings in fresh air into the home while expelling the stale air at the same time.
The heat recovery operation can help reduce the load on the ducted air conditioning system.
Filter (Supplied)
Filter cuts pollen and dust for fresh clean air. Replacement part no. P-220F-E. (G3 grade Classification :EN779:2012)
High Efficiency Supply Air filter (Optional)
The supply filter can be upgraded to the high efficency option, a non-washable high efficiency filter (M6 grade Classification :EN779:2012)
PZ-61DR-E wired 7 day controller (Optional)
Backlit LCD Lossnay remote controller allows you to program up to 8 separate Start/Stop patterns per day over a 7-day period. Controls 1 to 15 LGH~RVX-E Lossnay units. This controller is not required if a P-Series unit is installed with a wired controller (i.e.. PAR-32).
Night Purge (Requires PZ-61DR-E controller)
During the summer season, the Night Purge mode draws cooler outside air into the room at night. This energy conservation mode reduces the load when the air conditioning is started up the next morning. With new models, it is possible to manually engage and set the night purge operation.
Lossnay Ventilation Mode
Room air is discharged to outside via Lossnay core. Heat exchanged outside air is supplied to the room. In summer and winter, air conditioning energy can be recovered by Lossnay unit.
Bypass Ventilation Mode
Stale room air is discharged to outside without passing through the Lossnay core. In spring and autumn when air conditioning is not necessary, the unit operates in bypass ventilation mode.
Other Features
- Clean, fresh air
- Energy efficient heat recovery
- Air volume 417 l/s (model 150) to 694 l/s (model 250)
- Simultaneous air supply and exhaust stale air
- Heat recovery ventilation
- Use with Mr Slim and City Multi systems
- Fresh air without windows open
- Retains heat
- Washable supply air filter
Mitsubishi Electric Lossnay LGH-200RVXT-E Low-Profile – 556 L/s Heat Recovery Ventilation – Brochure
Description
556 l/s – Low Profile
Lossnay Ventilation Mode | Filter Included | Simultaneous air supply and exhaust