Multi Outdoor Unit | MON3H071 | ||
Maximum Number of connected Indoor Units | Qty | 3 | |
Power Supply (To Outdoor Unit) | V-Ph-Hz | 220~240 -1-50 | |
Cooling |
Rated Capacity (Range) | kW | 7. 1 (1.7 ~ 9.3) |
Rated Input Power | W | 1923 | |
Rated Input Current | A | 8.57 | |
AEER | W/W | 3.41 | |
Star Rating | 2.0 | ||
Non-operational Power | W | 18.0 | |
Heating |
Rated Capacity (Range) | kW | 7.4 (1.8 ~ 9.6) |
Rated Input Power | W | 1868 | |
Rated Input Current | A | 8.27 | |
ACOP | W/W | 3.79 | |
Star Rating | 3.0 | ||
Non-operational Power | W | 20.0 | |
Maximum Input Current | A | 14.5 | |
Compressor | Type | DC Twin Rotary | |
Sound Power Level |
dB(A) |
69 | |
Sound Pressure Level @ 1m | 60 | ||
Dimensions |
Net (W x D x H) |
mm |
845 x 363 x 702 |
Gross (W x D x H) | 965 x 395 x 755 | ||
Net / Gross Weight | kg | 55 / 59 | |
Refrigerant | Type | R32 | |
Refrigerant Piping |
Connection Size: Liquid Line |
mm |
3x Φ6.35 |
Connection Size: Gas | 3x Φ9.52 | ||
Maximum Total System Pipe Length |
m |
60 | |
Pre-Charged Length | 30 | ||
Maximum Length Per Indoor Unit | 25 | ||
Maximum Vertical Separation
Outdoor Unit ABOVE Indoor Unit |
10 | ||
Maximum Vertical Separation
Outdoor Unit BELOW Indoor Unit |
15 | ||
Maximum Height Difference Between Indoor Units | 10 | ||
Ambient Temperature Limits |
Cooling |
oC |
-15 ~ 50 |
Heating | -15 ~ 24 |