CAPACITY | 7.1 KW | |||
Set | FDU71AVNXWVH | |||
Indoor | FDU71VH | |||
Outdoor | FDCA71VNX-W | |||
Power Source (Outdoor Unit) | 1 Phase 240V 50Hz | |||
*Operation Data |
Nominal Capacity Range |
Cooling T1 |
kW |
7.1 (3.2-8.0) |
Heating H1 | 8.0 (3.6-9.0) | |||
Heating H2 | 7.40 | |||
Power Consumption |
Cooling T1 | 1.77 | ||
Heating H1 | 1.78 | |||
Max Power Consumption | 4.11 | |||
Running Current |
Cooling T1 |
A |
7.9 | |
Heating H1 | 7.9 | |||
Inrush Current, Maximum Current | 5, 20 | |||
EER | Cooling T1 | 4.01 | ||
COP | Heating H1 | 4.49 | ||
Sound Power Level (JS C9612) | Outdoor |
dB(A) |
66 | |
Sound Pressure Level (JS C9612) | Indoor | P-Hi:38 Hi:33 Me:29 Lo:25 | ||
Outdoor | 51 | |||
External Dimensions (HXWXD) |
Indoor |
mm |
280x950x635 | |
Outdoor | 750×880(+88)x340 | |||
Net Weight |
Indoor |
Kg |
34 | |
Outdoor | 60 | |||
Supply Air Connection |
mm |
170×880 | ||
Return Air Connection | 200X740 | |||
External Static Pressure (Max) | Pa | 200 | ||
Airflow | Indoor (Cooling) | l/s | P-Hi:400 Hi:316 Me: 250 Lo:166 | |
Indoor (Heating) | ||||
Refrigerant (Type, Amount, Pre-charge Length) |
Quantity | kg | (R32) 2.75 | |
Pre Charged To Pipe
Length |
m | 30 | ||
Installation Data |
Refrigerant Piping |
Liquid Line |
mm |
Ø9.52 |
Gas Line | Ø15.88 | |||
Connection Method | Flare Connection | |||
Maximum Pipe Length (One Way) |
m |
50 | ||
Max vertical height diff. between O.U. and I.U. |
30 ( O.U. above I.U. ) /
15 ( O.U. below I.U. ) |
|||
Controller | RC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2 | |||
Motion Sensor (Optional) | LB-KIT2 | |||
Demand response (AS4755) | Yes | |||
Outdoor air temperature (upper, lower limits) | Cooling |
oC |
-15 to 50 | |
Heating | -20 to 20 |
- Please choose product options by visiting DAIKIN FBA100B-VF2V 10.0kW Premium Inverter Slim-Line Ducted System 1 Phase.
Fully installed Mitsubishi Heavy Industries FDU71AVNXWVH 7.1kW Ducted System High Static Back lit Controller
Fully installed MITSUBISHI HEAVY INDUSTRIES FDU71AVNXWVH 7.1kW Ducted System High Static Back lit Controller
4 Outlets and 2 Zones
- Based on Single Storey dwelling
- Installed by Licensed and Arctick Certified Installers
- Outdoor unit to be placed on Concrete slab | PVC Slab | PVC Mounting Blocks.
- Weatherproof isolator placed at outdoor.
- Use of PVC or Colourbond Ducts.
- Includes electrical circuit up to 15 metres.
- 5 years full manufacturer warranty on Parts and Labour.
- Sydney, Central Coast and Newcastle Only
*T and C Applies
Description
7.1 kW Cooling
8.0 kW Heating
8.0 kW Heating
Home Leave Operation