FUJITSU SET-AGTG09KVCA 2.5kW Inverter Floor Console System | R32

SKU: SET-AGTG09KVCA

FUJITSU SET-AGTG09KVCA 2.5kW Inverter Floor Console System | R32

Apple-Catechin Filter | Long-Life Ion Deodorisation Filter | Connect Kit



Indoor unit AGTG09KVCA
Outdoor unit AOTG09KVCA
Operation Type Reverse Cycle
Power Source V/Ph/Hz 240 / 1 / 50
Cooling Capacity kW (Rated (Min – Max)) 2.50 (0.9 – 3.5)
Heating Capacity kW (Rated (Min – Max)) 3.50 (0.9 – 5.3)
Input Power Cooling kW (Rated (Max)) 0.53 (1.32)
Input Power Heating kW (Rated (Max)) 0.85 (1.66)
EER Cooling kW/kW 4.7
COP Heating kW/kW 4.27
Star Rating Cooling (0-10) (Hot / Average / Cold) 5.5 / 5 / 5
Star Rating Heating (0-10) (Hot / Average / Cold) 3 / 3 / 2.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 7.172 / 6.564 / 6.884
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.95 / 4.511 / 4.03
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 8.124 / 8.594 / 9.852
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.948 / 4.679 / 4.269
Running Current amps (Cooling / Heating) 3 / 4
Moisture Removal l/hr 1.3
Indoor Sound Pressure Cooling dBA (High / Quiet) 40 / 22
Indoor Sound Pressure Heating dBA (High / Quiet) 41 / 22
Outdoor Sound Pressure dBA (Cooling / Heating) 43 / 47
Outdoor Sound Power dBA 58
Air Circulation (Indoor – High Fan) Cooling l/sec 158
Air Circulation (Indoor – High Fan) Heating l/sec 167
Indoor Unit Dimensions mm (Height x Width x Depth) 600 x 740 x 200
Indoor Unit Weight kg 14.00
Outdoor Unit Dimensions mm (Height x Width x Depth) 542 x 799 x 290
Outdoor Unit Weight kg 31.00
Piping Connects mm Ø (Liquid / Gas) 6.35 / 9.52
Pipe Length m (Max (Precharged)) 20 (15)
Max Height Difference m 15
Operation Range Cooling °CDB (Min to Max) -10 to 46
Operation Range Heating °CDB (Min to Max) -15 to 24
Refrigerant Type R32

Key features

These units are installed to sit on the floor when wall space is limited.

  • All DC

    All DCWith All DC, electricity loss is decreased and power consumption reduced.

  • Apple Catechin Filter

    Apple-Catechin FilterFine dust, invisible mould spores and harmful microorganisms are absorbed onto the filter by static electricity and further growth is inhibited and deactivated by the polyphenol ingredient extracted from apples.

  • Auto Restart

    Auto RestartShould there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

  • Auto Shut Louvre

    Auto Shut LouvreThe auto shut louvres close or open automatically when the unit stops or starts.

  • Auto Changeover

    Auto ChangeoverThe unit automatically switches between operating modes based on the temperature setting and room temperature.

  • Automatic Air Flow Adjustment

    Automatic Air Flow AdjustmentThe micro-processor automatically adjusts the air flow to follow changes in room temperature.

  • Automatic Louvre

    Automatic LouvreThe position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.

  • Blue Fin Heat Exchanger

    Blue Fin Heat ExchangerCorrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.

  • Economy Mode

    Economy ModeLimits the maximum operation current, and performs operation with the power consumption suppressed.

  • Long Life Ion Deodorisation Filter

    Long-Life Ion Deodorisation FilterThe filter deodorises by powerfully decomposing absorbed odours using the oxidising and reducing effects of ion generated by the ultra-fine particle ceramic.

  • ON-OFF Timer

    On-Off TimerON-OFF timer can be set to operate once every 24 hours.

  • Powerful Mode

    Powerful ModePowerful mode will operate the indoor unit fan and outdoor unit compressor at maximum operation to quickly make the room conditioned and comfortable.

  • Program Timer

    Program TimerThis timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.

  • Sleep Timer

    Sleep TimerThe micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.

  • Super Quiet Mode

    Super Quiet ModeThe indoor units fan can operate at a low speed to produce quieter operation.

  • Up Down Swing

    Up/Down Swing LouvreThe up/down louvre automatically swings up and down.

  • v-PAM

    V-PAMv-PAM inverter technology increases the maximum output of the compressor significantly and enables high power and high efficiency.

  • Washable Panel

    Washable PanelDust that accumulates on the air conditioner can be easily cleaned with a damp cloth.

  • Weekly Timer

    Weekly TimerDifferent ON-OFF times can be set for up to 7 days.

  • Connect Kit

  • 10 Degree Heat

    10°C Heat OperationThe room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.

  • Low noise mode

    Outdoor Unit Low Noise ModeThe compressor speed and the outdoor unit fan speed are limited to reduce the operational noise.

  • Gas(Refrigerant) detector

  • 0.5°C Increments

Description

2.5 kW Cooling
3.5 kW Heating

Apple-Catechin Filter | R32

air conditioning enquiry