FUJITSU ABTG18LVTA 5.2kW Dual Floor | Under Ceiling Console System

SKU: SET-ABTG18LVTA

FUJITSU – Floor/Ceiling Console ABTG18LVTA
5.2kW Cooling Capacity
6.0kW Heating Capacity



Save: $914.00

$2,695.00

Save: $914.00

> > Compare
Model No. – Indoor ABTG18LVTA
Model No. – Outdoor AOTG18LACC
Reverse Cycle System Yes
Capacity Class
Cooling Capacity (Watts) 5,200
Cooling Capacity (BTU/h) 17,700
Range (Watts) 900-5,900
Range (BTU/h) 3,100-20,100
Heating Capacity (Watts) 6,000
Heating Capacity (BTU/h) 20,500
Range (Watts) 900-7,500
Range (BTU/h) 3,100-25,600
Power Supply (Volts) 230
Phase-Frequency (Ph – Hz) 1-50
Power Supply Attachment Outdoor
Plug Size (If Applicable) N/A
Running Current, Cooling (Amps) 6.4
Running Current, Range (Amps) Max: 9.6
Input, Cooling (Watts) 1,510
Input, Range (Watts) 1,820
Running Current, Heating (Amps) 7
Running Current, Range (Amps) Max: 13.1
Input, Heating (Watts) 1,660
Input, Range (Watts) 2,350
Input (Watts)
Moisture Removal (l/hr) 2
E.E.R. – Cooling 3.44
C.O.P. – Heating 3.61
Star Rating – Cooling 2
Star Rating – Heating 2.5
Fan Speed 4
Air Circulation, High (l/s) 217
Compressor Type Dc Twin Rotary
Dimensions – Inside Unit (HxWxD mm) 199 x 990 x 655
Weight – Inside Unit (kg) 27
Dimensions – Outside Unit (HxWxD mm) 620 x 790 x 290
Weight – Outside Unit (kg) 41
I.U. Sound Pressure Level (dBA@1mtr) 44
O.U. Sound Pressure Level (dBA@1mtr) 55
O.U. Sound Power Level (dBA) 71
Refrigerant Type R410A
Connection Pipe Sizes, Gas (mm) 12.7
Connection Pipe Sizes, Liquid (mm) 6.35
Pre Charged Length (Metre) 15
Minimum Pipe Length (Metre) 3
Maximum Pipe Length (Metre) 30
Maximum Pipe Height (Metre) 20
Pipe Connection Methods Flare
Outdoor operating Temp, Cooling ℃ -10 to 46
Outdoor operating Temp, Heating ℃ -15 to 24

Up/Down Swing Louvre

The up/down louvre automatically swings up and down.

Auto Shut Louvre

The auto shut louvres close or open automatically when the unit stops or starts.

Auto Restart

Should there be temporary loss of power; the unit will automatically restart itself in the same operating mode, once the power is restored.

Program Timer

This timer allows selection of one of four options. ON, OFF, ON > OFF, or OFF > ON.

ON-OFF Timer

ON-OFF timer can be set to operate once every 24 hours.

Blue Fin Heat Exchanger

Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchange.

Double Swing Automatic

Complex swing action of the louvres enables them to swing automatically in both horizontal and vertical directions.

Automatic Louvre

The position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.

Automatic Air Flow Adjustment

When auto mode is selected for the fan, the micro-processor adjusts the airflow to follow changes in room temperature.

Sleep Timer

The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.

Economy mode

Limits the maximum operation current, and performs operation with the power consumption suppressed.

ALL DC

With All DC, electricity loss is decreased and power consumption reduced.

Auto-Changeover

The unit automatically switches between heating and cooling modes based on the temperature setting and room temperature.

Description

5.2 kW Cooling
6.0 kW Heating

DOUBLE SWING AUTOMATIC