Technical Information | ||
OUTDOOR MODEL | CRV180T | |
INDOOR MODEL | EVV180S | |
1 Total (Gross) Capacity (kW) (AS/NZS3823.1.2) | Cooling (Rated) | 16.30 |
Heating (Rated) | 16.70 | |
Nett (Rated) Capacity (kW) (AS/NZS3823.1.2) | Cooling (Min/Rated/Â Â Â Â Â Â Â Â Â Â Â Â ) | 3.75 / 16.00 / 18.00 |
Heating (Min/Rated/Â Â Â Â Â Â Â Â Â Â Â Â ) | 3.85 / 17.00 / 19.00 | |
Input Power (kW) (AS/NZS3823.1.2) | Cooling (Rated) | 4.86 |
Heating (Rated) | 4.91 | |
2 EER Rated (AS/NZS3823.1.2)
3 COP Rated (AS/NZS3823.1.2) |
Cooling (Rated) | 3.29 |
Heating (Rated) | 3.46 | |
Â
Power Supply (V / Ph / Hz) |
Outdoor | 400V / 3Ph + N / 50Hz |
Indoor | 230V / 1Ph + N / 50Hz | |
Rated Load Amps (AS/NZS3823.1.2) Full Load Amps (AS/NZS3823.1.2) | Outdoor / Indoor / Total | 7.8 / 2.7 / 10.5 |
Outdoor / Indoor / Total | 11.8 / 4.4 / 16.2 | |
4 Circuit Breaker Amps | 20.0 | |
Â
IP Rating |
Outdoor | IP44 |
Indoor | IP20 | |
Â
Compressor |
Type / No. per Unit | Tru-Inverter Variable Speed Scroll / 1 |
Starting Method | Inbuilt Soft Starting | |
No. Refrigeration Circuits/No. Capacity Stages (Capacity range) | 1 / Variable Capacity (20-100%) | |
Refrigerant | R410A | |
Â
Fans (Type x Number per unit) |
Outdoor | Axial / 6 Pole External Rotor / Direct Drive x 2 |
Indoor | Twin Deck Centrifugal / ECM Direct Drive x 1 | |
Â
Airflow Range Indoor (l/s) |
Maximum | 1020 |
Nominal | 850 | |
Minimum | 680 | |
Â
Outdoor Dimensions (mm) |
Depth | 580 |
Height | 1045 | |
Width | 1460 | |
Â
Indoor Dimensions (mm) |
Depth | 680 |
Height | 435 | |
Width | 1420 | |
Â
5 Nominal Weight (kgs) |
Outdoor | 155 |
Indoor | 69 | |
6 Sound Pressure Level (dBA)
7 Sound Power Level (dBA) |
Outdoor (low/high fan) | 47.1 / 48.3 / 52.1 |
Outdoor (low/high fan) | 66.3 / 67.8 / 71.5 | |
MEPS Compliant | Yes | |
8 Demand Response Capability (AS4755.3) | Capable |
ActronAir Advance CRV180T | EVV180S 16kW Split Ducted System | 3 Phase
ActronAir Advance CRV180T / EVV180S 16kW Split Ducted Systems – Three Phase
Includes 7 day wall controller – 8 Zone
What’s an Inverter, and what’s a Tru-Inverter?
Unlike conventional inverter compressors, which use ‘step, rest and stop’ cycles that cause the temperatures to jump up and down each step, the Tru-Inverter is vastly more precise, getting to the desired temperature faster, smoother, and maintaining it to within +/- 0.3°C at the sensor location – that means more comfort and a more comfortable electricity bill.
Why choose a Tru-Inverter?
Tru-Inverter can operate down to 20% of capacity for improved efficiency, as opposed to conventional inverters which can only operate down to 40% of capacity. Not only that, it can also heat and cool your home a phenomenal 5 times faster than conventional inverter systems.
To view the Brochure
Click here
Description
16.0 kW Cooling
17.0 kW Heating
Tru-Inverter | Quiet Mode