ActronAir 16.8kW CCA170S / EAA170S Add On Cooling Split Ducted Systems | Single Phase

SKU: CCA170S / EAA170S

ActronAir 16.8kW CCA170S / EAA170S Add On Cooling Split Ducted Systems

Optional available Supply Air Vbox:

Supported Insulated Copper Pair Coil




> > Compare
OUTDOOR MODEL CCA170S
INDOOR MODEL EAA170S
1 Nominal Capacity (kW) (low/med/high) 16.65/16.96/17.49
1 Nominal Input Power (low/med/high) 4.55/4.57/4.59
1 Nominal EER (low/med/high) 3.66/3.71/3.81
Nett Capacity (kW) (low/med/high) 16.50(2)/16.80/17.30
Nett Input Power (kW) (low/med/high) 4.70(2)/4.73/4.77
Nett EER (low/med/high) 3.51(2)/3.55/3.63
Airflow Indoor (l/s) (low/med/high) 765/840/980
Coil Static Pressure Drop (Wet/Dry) Pa 102/73
Power Supply – (V/Ph/Hz) 230V / 1Ph+N / 50Hz
Outdoor Unit Rated Amps (AS/NZS3823.1.2) 20.2
Outdoor Unit Full Load Amps (AS/NZS3823.1.2) 30.7
3 Circuit Breaker Amps 40.0
IP Rating Outdoor Unit IP44
 

Compressor

Type/No. per Unit Compliant Scroll / 1
Starting Method Soft Starter
No. of refrigeration Circuits/No of capacity stages (Capacity range) 1/1 (100% capacity)
Refrigerant R410A
Fans (Type x Number per unit) Outdoor Axial / 6 Pole External Rotor / Direct Drive x 2
 

Outdoor Dimensions (mm)

Depth 580
Height 1045
Width 1460
 

Indoor Dimensions (mm)

Depth 342
Height 410
Width 1252
 

4 Nominal Weight (kgs)

Outdoor 156
Indoor 29
 

Field Pipe Size

Maximum Field Pipe Length Range – (m) 0 – 60
Liquid Pipe – mm (inch) 9.52 (3/8)
Gas Pipe – mm (inch) 19.05 (3/4)
5 Sound Pressure Level (dBA)

6 Sound Power Level (dBA)

Outdoor (low/med/high fan) 50.4 / 51.3 / 53.1
Outdoor (low/med/high fan) 69.8 / 70.7 / 73.1
MEPS Compliant Yes
8 Demand Response Capability (AS4755.3) Capable

 

More ducting options
The Add On system’s indoor unit has a range of duct adaptor options to suit most duct works.

Safety Drain Tray included as standard

Removes the need to purchase as an additional accessory.


Louvered Grille

The Add On’s powder coated louvered grille guard allows for better airflow and protection against Australia’s extreme weather conditions.

Coated Coil Protection

The Add On uses blue fin epoxy coated protection on its indoor and outdoor coils, which helps to reduce corrosion from the harsh Australian conditions.

Quieter Operation

The Add On features a 3 speed outdoor fan, allowing for smoother, quieter operation.

Click here to view the brochure of ActronAir Add On Cooling Split Ducted Systems

Description

16.80 kW Cooling
Includes 24V Relay

air conditioning enquiry