The Daikin Bulkhead Air Conditioning range is the ideal choice for air conditioning areas where a discreet installation is preferred.
The indoor unit fits flush into the ceiling with only the suction air and discharge grilles visible inside your home and leaving maximum floor and wall space for furniture, decoration and fittings. The Bulkhead range is truly discreet with whisper quiet operations to ensure limited impact to internal room aesthetics and acoustics.
DAIKIN FDYBA25AV1 / RZAC25GV1 2.5kW Inverter Bulkhead System Single Phase
DAIKIN FDYBA35AV1 / RZAC35GV1 3.5kW Inverter Bulkhead System Single Phase
DAIKIN FDYBA50AV1 / RZAC50GV1 5.0kW Inverter Bulkhead System Single Phase
DAIKIN FDYBA60AV1 / RZAC60GV1 6.0kW Inverter Bulkhead System Single Phase
DAIKIN FDYBA71AV1 / RZAC71GV1 7.1kW Inverter Bulkhead System Single Phase
Compact Performance
Offering maximum performance in a compact, 450mm deep package, this model is ideal for wardrobe installations.
Quiet Operation
Noise levels are truly discreet and whisper-quiet at 19dBA (low fan speed, 35 Class Model).
Flexible Return Air
The option of a rear or bottom suction return allows for greater installation flexibility.
Built-in condensate pump
DC condensate pump is equipped as standard with a 750mm lift.
3-D Auto Swing Grille (Option)
Vertical & horizontal motorised louvres installed provide 3-D airflow distribution, circulating air to all corners of the room.Vertical & horizontal motorised louvres installed provide 3-D airflow distribution, circulating air to all corners of the room.
Auto Clean Air Filter Module (Option)
This module keeps the internal filter clean by collecting dust and storing it in a convenient vacuum port for easy removal.
^BAE20A62 for 25 Class, BAE20A82 for 35-50 Class & BAE20A102 for 60-71 Class (all models extend depth by 188mm). Only compatible with BRC1E63 controller.
INDOOR UNIT | FDYBA25AV1 | FDYBA35AV1 | FDYBA50AV1 | FDYBA60AV1 | FDYBA71AV1 | |
OUTDOOR UNIT | RZAC25GV1 | RZAC35GV1 | RZAC50GV1 | RZAC60GV1 | RZAC71GV1 | |
Rated Capacity | Cool (kW) | 2.50 | 3.50 | 5.00 | 6.00 | 7.10 |
Heat (kW) | 3.50 | 4.00 | 6.00 | 7.00 | 8.00 | |
Capacity Range | Cool (kW) | 0.8-2.8 | 0.8-4.0 | 1.6-6.2 | 2.0-6.7 | 1.7-7.6 |
Heat (kW) | 0.9-3.7 | 1.0-4.3 | 1.5-7.4 | 2.0-8.0 | 1.4-8.6 | |
Power Input (Rated) | Cool (kW) | 0.59 | 1.00 | 1.36 | 1.67 | 2.12 |
Heat (kW) | 0.97 | 1.10 | 1.73 | 1.80 | 2.20 | |
E.E.R/C.O.P | C/H | 4.24/3.63 | 3.5/3.64 | 3.69/3.48 | 3.59/3.89 | 3.36/3.64 |
TCSPF (Residential) | Hot/Average/Cold | 4.85/4.20/4.15 | 4.39/3.94/3.99 | 5.10/4.22/4.23 | 5.22/4.41/4.48 | 4.62/4.29/4.46 |
HSPF (Residential) | Hot/Average/Cold | 4.29/3.64/3.05 | 4.53/4.06/3.69 | 4.76/4.12/3.58 | 5.28/4.58/3.98 | 6.09/4.13/3.28 |
Airflow Rate (Rated) | l/s | 150 | 195 | 240 | 325 | 325 |
Indoor Sound Level (H) @ 1.5m | Discharge (dBA) | 41.6 | 43.1 | 45.3 | 47.7 | 47.7 |
Suction (dBA) | 40.8 | 38.9 | 41.2 | 46.2 | 46.2 | |
Casing Breakout (dBA) | 30.1 | 31.6 | 33.8 | 35.6 | 35.6 | |
Piping Length | m | 20 | 20 | 30 | 30 | 30 |
Indoor Fan Speeds | 5 Steps, Quiet and Automatic | |||||
Dimensions (HxWxD) | Indoor (mm) | 200x700x450 | 200x900x450 | 200x1100x450 | ||
Outdoor (mm) | 550x675x284 | 595x845x300 | 695x930x350 | |||
Weight | Indoor (kg) | 18 | 21 | 24 | ||
Outdoor (kg) | 28 | 64 | 128 | |||
Power Supply | V/Hz | 1 Phase 220-240V, 50Hz | ||||
Compressor Type | Hermetically Sealed Swing Type | |||||
Refrigerant | R32 | |||||
Pipe Sizes | Liquid (mm) | 6.4 (Flared) | 6.4 (Flared) | |||
Gas (mm) | 9.5 (Flared) | 12.7 (Flared) | ||||
Drain (mm) | ID 20 / OD 26 | |||||
Supply Air Opening | mm (HxW, Flange) | 153×660 | 153×860 | 153×1060 | ||
Return Air Opening | mm (HxW, Flange) | 163×575 | 163×775 | 163×975 | ||
Outdoor Operating Range | Cool (°CDB) | -10 to 50 | ||||
Heat (°CWB) | -15 to 18 | |||||
EPA Sound Power Level | dBA | 60 | 60 | 62 | 63 | 67 |
Outdoor Sound Level (H) @ 1m | Pressure dBA (C/H) | 45/48 | 47/48 | 47/50 | 48/51 | 53/55 |