SAMSUNG Free Joint Multi Air Conditioning RJ100F5HXEAXSA 10.0kW Outdoor Only

SAMSUNG Free Joint Multi Air Conditioning RJ100F5HXEAXSA 10.0kW Outdoor Only

Check Delivery Cost
  • For Advanced Installations, please click here to Request a Quote
  • Please note: All products come with a 5 year standard manufacturers warranty
Model: RJ100F5HXEAXSA Samsung Free Joint Multi Air Conditioning Reverse Cycle Inverter Twin Rotary / Outdoor Unit Only 10.0kW Cooling - 12.0kW Heating Capacity / 5 indoor units
Quantity:

Our Price:
$ 2280.00



Model Name RJ100F5HXEAXSA
Power Supply ∅, #, V, Hz 1, 2, 220~240, 50
Mode - Heat Pump
Performance HP HP 3.5
Capacity Input (Nominal) Cooling1 kW 10.0
Btu/h 34,100
Heating2 kW 12.0
Btu/h 40,900
Power Power Input (Nominal) Cooling1 kW 2.90
Heating2   2.93
Current Input (Nominal) Cooling1 A 13.30
Heating2   13.40
Energy Efficiency  Nominal Cooling1 - 3.45
Nominal Heating1 - 4.10
Compressor Type  - Inverter Twin Rotary 
Model Name  - UG8T300FUBJU
Oil Type - POE
Initial Charge cc 1200
Fan Type  - Propeller Fan/ BLDC
Output W 150
Number of Units EA 1
Air Flow Rate CMM 70.6
Piping Connections Liquid Pipe ∅, mm 6.35 x 5
∅, inch 1/4 x 5
Gas Pipe ∅, mm 9.52 x 2 + 12.7 x 3
∅, inch 3/8 x 2 + 1/2 x 3
Installation Limitation Total Piping Length m 80.0
Max. Length (Outdoor to indoor) m 25.0
Max. Height (Between indoors) m 7.5
Max. Height (Between ID/OD) m 15.0
Refrigerant Type  - R410A
Factory Charging kg 3.3
Sound3 Sound Pressure dB(A) 52
External Dimension Net Weight  kg 75
Shipping Weight kg 80
Net Dimensions (WxHxD) mm 940 x 998 x 330
Shipping Dimensions (WxHxD) mm 995 x 1,096 x 426
Operating Temp. Range Cooling ˚C  -10 ~ 26
Heating  ˚C -15 ~ 24

1) Nominal cooling capacities are based on; Indoor temperature : 27˚C DB, 19˚C WB / Outdoor temperature : 35˚C DB, Equivalent refrigerant piping : 5m(10kW), 7.5m(7/8kW), Level differences : 0m

2) Nominal heating capacities are based on; Indoor temperature : 20˚C DB, 15˚C WB / Outdoor temperature : 7˚C DB, 6˚C WB, Equivalent refrigerant piping : 5m(10kW), 7.5m(7/8kW), Level differences : 0m

3) Sound level was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.


 